Page 20 RS-500/600 Door Part No 4801-5166 Rev 01-2015
11 Emergency Egress (Optional Feature)
The Emergency Egress feature provides a simple and convenient means of exiting a RollSeal RS-500/600 Door
from the inside of the structure should the door motor become inoperative due to a power failure or other conditions.
11.1 Installation
Install the two Strap Retainers (1040-8400) to the left or right side outside of door jamb as shown below. For
a wood framed door jambs use two #10 x1 screws (1004-1386). For a metal framed door jamb use two
#8x1/2 Tek screws (1004-2492). See Diagram 11A.
Diagram 11A
Diagram 11B
11.2 Exiting (Opening) The Door
1. Remove Emergency Egress Tool
from the retainers on the side of
the door.
2. Connect the hook end of the tool
to the D-Ring on the top of the
door frame. See Diagram 11B.
3. Pull down on the Egress Strap.
The Door will raise
approximately half way up. The
door will open enough for a
person to exit the structure. See
Diagram 11C.